Please ensure that you can provide as much information as possible if you are looking for a spare as this will speed up the reply to your query.
We only supply our customers with Genuine Manufacturers parts, no copy parts are sold as we consider these unsafe and unreliable.
Baxi Parts: Supply and Fit
Baxi Pressure Vessel
New pressure vessels fitted
Baxi Circuit Boards
Baxi electrical faults repaired using Baxi OEM components Baxi sensors and thermostats checked to identify the source of the electrical fault
Baxi Air Pressure Switch
Fuel combustion requires sufficient oxygen New Air flow-pressure systems fitted
Baxi Flame Sensing Electrode
The Baxi Flame sensor detects when the flame is ignited and tends to fail safe, a faulty flame sensing electrode will normally prevent the boiler from igniting
Baxi Pressure Guage
OEM Baxi parts fitted or replaced with alternative pressure guages
Baxi Automatic Air Vent
Sticking or damaged air vents replaced
Baxi Thermistor
Baxi faulty temperature sensitive thermistors replaced
Baxi Ignition Pilot Systems
When a boiler does not have automatic ignition the gas pilot light should be permanently lit to ignite the main burner as required;
Auto ignition Boiler Systems can use a temporary pilot light in order to light the main burners without relying on a spark that could allow a dangerous build up of gas
Modulating Burner Systems can start on a very low flame, hence ignited directly before the gas flow increases
Baxi Microswitches
Baxi microswitches eventuallly wear or contacts fail to work New microswitches fitted
Baxi Timer and Replacement Timers
Baxi timers : Rather than have your central heating come on as the temperature falls slightly; the timer allows you to control your home temperature and heating costs
Set the timer to switch on about an hour before you normally get up in the morning and switch off an hour or so before your usual bedtime
Combine the timer with a thermostat for optimal temperature control
Baxi Thermostat
Baxi replacement boiler thermostats The thermostat responds to changes in water temperature to ensure the boiler remains within safe operating temperature limits arrange to have your Baxi boiler inspected if the water temperature is fluctuating unusually during normal use
Baxi Divertor Valve
Baxi divertor valves replaced for most Baxi boiler systems
Baxi Thermocouple
Thermocouples convert temperature into movement or voltage change: most sensing thermocouple replaced
Baxi Fan
Replacement Baxi fans installed
Baxi Flow Sensor
Gas Flow and Water Flow sensing elements replaced
Baxi Water Pumps
Baxi pumps circulate the water to the radiators during the central heating cycle in combination boiler systems - In sealed systems ensure the water pressure is sufficient and that the radiators aren't air filled and require bleeding
Baxi Compatible Room Thermostat
Replacement Baxi thermostats fitted to maintain a comfortable room temperature and minimise your heat energy costs